Review





Similar Products

90
Blackrock Microsystems LLC utah electrode arrays ueas
Utah Electrode Arrays Ueas, supplied by Blackrock Microsystems LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utah electrode arrays ueas/product/Blackrock Microsystems LLC
Average 90 stars, based on 1 article reviews
utah electrode arrays ueas - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Blackrock Microsystems LLC utah electrode array (uea)
Utah Electrode Array (Uea), supplied by Blackrock Microsystems LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utah electrode array (uea)/product/Blackrock Microsystems LLC
Average 90 stars, based on 1 article reviews
utah electrode array (uea) - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Blackrock Neurotech utah electrode arrays (ueas)
Utah Electrode Arrays (Ueas), supplied by Blackrock Neurotech, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utah electrode arrays (ueas)/product/Blackrock Neurotech
Average 90 stars, based on 1 article reviews
utah electrode arrays (ueas) - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Blackrock Microsystems LLC utah electrode arrays (ueas)
Electrograms recorded using <t>an</t> <t>electrode</t> of the UEA implanted at HB-region. (A, top) The Atrial, His-Bundle and Ventricular (V) activations are shown by the arrows (blue) and marked as A, HB and V respectively. (A, center) The spatial derivative highlighted the electrode’s local electrical activity by subtracting the surrounding electrode’s electrical signal from the central electrode’s electrical information. (A, bottom) The time derivative of the spatial derivative signal highlights the HB electrical activity (bottom). (B) pseudo-ECG while pacing through an electrode of the UEA. ‘P’ indicates the pacing artifact. T1=pace interval and T2=R-R interval. (B, top) Pacing HB at lower current utilizing an electrode from UEA, T1≠T2. (B, center) Pacing continued until HB captured, T1=T2. Inset shows that QRS complex while HB captured and is of similar morphology as the QRS of pseudo-ECG when HB is not captured. (B, bottom) <t>UEA’s</t> electrode is on working myocardium location beside HB-region. Instead of pacing HB, WM was paced and captured, T1=T2. The inset shows the QRS complex while WM is captured and the morphology is significantly different in comparison with QRS complex while HB is captured. QRS insets of HB and WM paced beats are of different shapes with durations of 32 ms and 40 ms, respectively. Electrograms recorded through 96 electrodes of UEA while implanted in HB-region are shown in Fig. 6.
Utah Electrode Arrays (Ueas), supplied by Blackrock Microsystems LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utah electrode arrays (ueas)/product/Blackrock Microsystems LLC
Average 90 stars, based on 1 article reviews
utah electrode arrays (ueas) - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Blackrock Microsystems LLC utah electrode array uea
Electrograms recorded using <t>an</t> <t>electrode</t> of the UEA implanted at HB-region. (A, top) The Atrial, His-Bundle and Ventricular (V) activations are shown by the arrows (blue) and marked as A, HB and V respectively. (A, center) The spatial derivative highlighted the electrode’s local electrical activity by subtracting the surrounding electrode’s electrical signal from the central electrode’s electrical information. (A, bottom) The time derivative of the spatial derivative signal highlights the HB electrical activity (bottom). (B) pseudo-ECG while pacing through an electrode of the UEA. ‘P’ indicates the pacing artifact. T1=pace interval and T2=R-R interval. (B, top) Pacing HB at lower current utilizing an electrode from UEA, T1≠T2. (B, center) Pacing continued until HB captured, T1=T2. Inset shows that QRS complex while HB captured and is of similar morphology as the QRS of pseudo-ECG when HB is not captured. (B, bottom) <t>UEA’s</t> electrode is on working myocardium location beside HB-region. Instead of pacing HB, WM was paced and captured, T1=T2. The inset shows the QRS complex while WM is captured and the morphology is significantly different in comparison with QRS complex while HB is captured. QRS insets of HB and WM paced beats are of different shapes with durations of 32 ms and 40 ms, respectively. Electrograms recorded through 96 electrodes of UEA while implanted in HB-region are shown in Fig. 6.
Utah Electrode Array Uea, supplied by Blackrock Microsystems LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utah electrode array uea/product/Blackrock Microsystems LLC
Average 90 stars, based on 1 article reviews
utah electrode array uea - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

Image Search Results


Electrograms recorded using an electrode of the UEA implanted at HB-region. (A, top) The Atrial, His-Bundle and Ventricular (V) activations are shown by the arrows (blue) and marked as A, HB and V respectively. (A, center) The spatial derivative highlighted the electrode’s local electrical activity by subtracting the surrounding electrode’s electrical signal from the central electrode’s electrical information. (A, bottom) The time derivative of the spatial derivative signal highlights the HB electrical activity (bottom). (B) pseudo-ECG while pacing through an electrode of the UEA. ‘P’ indicates the pacing artifact. T1=pace interval and T2=R-R interval. (B, top) Pacing HB at lower current utilizing an electrode from UEA, T1≠T2. (B, center) Pacing continued until HB captured, T1=T2. Inset shows that QRS complex while HB captured and is of similar morphology as the QRS of pseudo-ECG when HB is not captured. (B, bottom) UEA’s electrode is on working myocardium location beside HB-region. Instead of pacing HB, WM was paced and captured, T1=T2. The inset shows the QRS complex while WM is captured and the morphology is significantly different in comparison with QRS complex while HB is captured. QRS insets of HB and WM paced beats are of different shapes with durations of 32 ms and 40 ms, respectively. Electrograms recorded through 96 electrodes of UEA while implanted in HB-region are shown in Fig. 6.

Journal: ACS biomaterials science & engineering

Article Title: In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle

doi: 10.1021/acsbiomaterials.0c00065

Figure Lengend Snippet: Electrograms recorded using an electrode of the UEA implanted at HB-region. (A, top) The Atrial, His-Bundle and Ventricular (V) activations are shown by the arrows (blue) and marked as A, HB and V respectively. (A, center) The spatial derivative highlighted the electrode’s local electrical activity by subtracting the surrounding electrode’s electrical signal from the central electrode’s electrical information. (A, bottom) The time derivative of the spatial derivative signal highlights the HB electrical activity (bottom). (B) pseudo-ECG while pacing through an electrode of the UEA. ‘P’ indicates the pacing artifact. T1=pace interval and T2=R-R interval. (B, top) Pacing HB at lower current utilizing an electrode from UEA, T1≠T2. (B, center) Pacing continued until HB captured, T1=T2. Inset shows that QRS complex while HB captured and is of similar morphology as the QRS of pseudo-ECG when HB is not captured. (B, bottom) UEA’s electrode is on working myocardium location beside HB-region. Instead of pacing HB, WM was paced and captured, T1=T2. The inset shows the QRS complex while WM is captured and the morphology is significantly different in comparison with QRS complex while HB is captured. QRS insets of HB and WM paced beats are of different shapes with durations of 32 ms and 40 ms, respectively. Electrograms recorded through 96 electrodes of UEA while implanted in HB-region are shown in Fig. 6.

Article Snippet: Utah electrode arrays (UEAs) were custom designed and fabricated at Blackrock Microsystems, Salt Lake City, UT.

Techniques: Activity Assay, Comparison